Hardware Maintenance Manual: xSeries 250
 
 
Power supply LED errors
Use the power supply LED information on the following page to troubleshoot power 
supply problems.
Note:
The minimum configuration required for the DC Good light to come on is: 
Power Supply
Power Backplane
Processor/PCI Board (with pins 2 and 3 on J23 connected together to 
bypass the power switch; see “Processor board jumpers” on page 57).
Processor/PCI Board (Verify that Processor/PCI Board and I/O Legacy 
Board are properly connected together; see “Processor board component 
locations” on page 55
.
Power switch does not work and 
reset button does work.
1.
Verify that the power-on control jumper on J23 is 
on pins 1 and 2.
2.
Power Switch Assembly
3.
I/O Legacy Board
Diskette drive in-use light stays 
on, or the system bypasses the 
diskette drive, or the diskette 
drive does not work.
1.
If there is a diskette in the drive, verify that:
 
a.
The diskette drive is enabled in the 
Configuration/Setup utility program.
b.
The diskette is good and not damaged.   (Try 
another diskette if you have one.)
c.
The diskette is inserted correctly in the drive.
d.
The diskette contains the necessary files to 
start the server.
e.
The software program is OK.
f.
Cable is installed correctly (proper orientation)
2.
Run Diskette Drive Diagnostics.
3.
Cable
4.
Diskette Drive
5.
I/O Legacy Board
Monitor problems (general).  
Some IBM monitors have their 
own self-tests.  If you suspect a 
problem with the monitor, refer to 
the information that comes with 
the monitor for adjusting and 
testing instructions.
1.
Monitor
2.
Run Video Diagnostics.  If diagnostics pass, the 
problem may be a video driver.
3.
Display Adapter / I/O Legacy Board
AC Good 
LED
DC Good 
LED
Description
FRU/Action
Off
Off
No power to system or 
ac problem.
1.
Check ac power to system.
2.
Power Supply
Error Symptom
FRU/Action