IBM 71Y Manuale Utente
156
Hardware Maintenance Manual: xSeries 250
129
(Internal cache error)
1.
Processor
2.
Optional processor (if installed)
3.
Processor/PCI board
151
(Real time clock error)
1.
Run Diagnostics
2.
Battery
3.
I/O Legacy Board
161
(Real time clock battery
error)
1.
Run Configuration/Setup
2.
Battery
3.
I/O Legacy Board
162
(Device Configuration
Error)
Note:
Be sure to load the
default settings and any
additional desired
settings; then, save the
configura-tion.
default settings and any
additional desired
settings; then, save the
configura-tion.
1.
Run Configuration/Setup
2.
Battery
3.
Failing Device
4.
I/O Legacy Board
163
(Real-Time Clock error)
1.
Run Configuration/Setup
2.
Battery
3.
I/O Legacy Board
164
(Memory configuration
changed, see "Memory Settings"
on page 49.)
on page 49.)
1.
Run Configuration/Setup
2.
DIMM
3.
Processor/PCI Board
175
(Hardware error)
1.
I/O Legacy Board
2.
Processor/PCI Board
176
(Computer cover or cable
cover was removed without a
key being used)
key being used)
1.
Run Configuration/Setup
2.
I/O Legacy Board
3.
C2 Security Switch
177, 178
(Security hardware
error)
1.
Run Configuration/Setup
2.
I/O Legacy Board
184
(Power-on password
corrupted)
1.
Run Configuration/Setup
2.
I/O Legacy Board
185
(Drive startup sequence
information corrupted)
1.
Run Configuration/Setup
2.
I/O Legacy Board
186
(Security hardware control
logic failed)
1.
Run Configuration/Setup
2.
I/O Legacy Board
187
(VPD serial number not set.) 1.
Set serial number in Setup
2.
I/O Legacy Board
188
(Bad EEPROM CRC #2)
1.
Run Configuration/Setup
2.
I/O Legacy Board
189
(An attempt
was made to access the server
with invalid passwords)
with invalid passwords)
1.
Run Configuration/Setup, enter the administrator
password
password
2.
I/O Legacy Board.
Error Code/Symptom