7
Table 60501-2.  Programming Ranges (continued)
Transient Operation
Set Frequency
FREQ value
"TRAN:FREQ value"
0.25 Hz to 10 kHz
Set Duty Cycle
(shift) 
DCYCLE value
"TRAN:DCYC value"
3-97% (0.25 Hz-1 kHz)
6-94% (1 kHz-10 kHz)
*Set Pulse Width
"TRAN:TWID value"
0.00005 to 4 s
Trigger Operation
*Set Trigger Period
"TRIG:TIM value"
0.000008 to 4 s
Current Protection
*Set Current Level
"CURR:PROT value"
0 to 30.6 A
*Set Delay Time
"CURR:PROT:DEL value"
0 to 60 s
*Can only be programmed remotely via the GPIB.
Table 60501-3.  Factory Default Settings
Function
Settings
Function
Setting
CURR level
0 A
Mode (CC, CR, CV)
CC
CURR transient level
0 A
Input (on/off)
on
*CURR slew rate
0.5 A/
µ
s
Short (on/off)
off
CURR range
30 A
Transient operation (on/off)
off
*CURR protection (on/off)
off
***TRAN mode
continuous
**CURR protection level
30.6 A
(continuous, pulse, toggle)
**CURR protection delay
15 s
TRAN frequency
1 kHz
TRAN duty cycle
50%
RES level
2 k
Ω
**TRAN pulse width
0.5 ms
RES transient level
2 k
Ω
RES range
2 k
Ω
**TRIG source
hold
(bus, external, hold, timer, line)
VOLT level
60 V
**TRIG period
0.001 s
VOLT transient level
60 V
**PORT0 output (on/off)
off (logic 0)
VOLT slew rate
5 V/
µ
s
**CAL mode (on/off)
off
The *RST command resets the CURR slew rate to 2.5 A/
µ
, not to the factory default.
**Can only be programmed remotely via the GPIB.
***Continuous transient mode is the only mode available at the front panel.  Pulsed, toggled, and continuous modes can
      all be programmed remotely via the GPIB.