Message Formats
Property Management System - Communication Interface
Restriction Control
There are two messages. They are identical, except that message 15-1 is sent from
the PMS to the NEAX, and message 15-2 is sent by the NEAX to the PMS. These
messages simply communicate a new restriction code for an extension. These
messages are used by both the Model 60 and the Model 90 version.
the PMS to the NEAX, and message 15-2 is sent by the NEAX to the PMS. These
messages simply communicate a new restriction code for an extension. These
messages are used by both the Model 60 and the Model 90 version.
Figure 4-9 Restriction Control
Message fields are:
•
FC-- There are two functions: (FTC-FC)
•
15-1 -- Originated from the PMS.
•
15-2 -- Originated from the NEAX.
•
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
left justify the number and fill the remaining bytes with space (20H) characters.
•
Code -- Restriction code for this extension. The possible codes are:
•
0 -- Do Not Disturb and Room Cut-Off are cancelled.
•
1 -- Room Cut-Off is set, Do Not Disturb is cancelled.
•
5 -- Do Not Disturb is set, Room Cut-Off is cancelled.
•
6 -- Do Not Disturb and Room Cut-Off are set.
•
Blank -- Field contains two space (20H) characters.
‘1’ ‘5’
‘1’
‘4’
** Extension
Code
** Multiple Function Codes use this message. See below.
0
1
2
3
4
6
8
9
15
STX
SA
UA
EI
FTC
MSC
FC
6
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
2
16
18
19
Blank