NEC NDA-30115-001 Manuale Utente
NDA-30115 Revision 1.0
Page 71
Property Management System - Communication Interface
Message Formats
Extension
Assignment
Report
Assignment
Report
Figure 4-46 Extension Assignment Report
Message fields are:
•
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
left justify the number and fill the remaining bytes with space (20H) characters.
•
Def -- Defines the extension to be either an administration extension or a guest
extension. Codes are:
extension. Codes are:
•
0 -- Administration
•
1 -- Guest
•
Class -- The room class designated at the time of extension assignment.
‘1’
‘7’ ‘1’
‘3’
‘F’ Extension
Def
Class
0
1
2
3
4
6
8
9
15
STX
SA
UA
EI
FTC
MSC
FC
6
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
1
16
17
18