NEC NDA-30115-001 ユーザーズマニュアル

ページ / 116
NDA-30115  Revision 1.0
Page 71
Property Management System - Communication Interface
Message Formats
Extension 
Assignment 
Report
Figure 4-46   Extension Assignment Report
Message fields are:
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
Def -- Defines the extension to be either an administration extension or a guest 
extension. Codes are:
0 -- Administration
1 -- Guest
Class -- The room class designated at the time of extension assignment.
‘1’
‘7’ ‘1’
‘3’
‘F’ Extension
Def
Class
0
1
2
3
4
6
8
9
15
STX
SA
UA
EI
FTC
MSC
FC
6
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
1
16
17
18