Omron CS1W-RPT01 Manuale Utente

Pagina di 401
190
Using the Message Service
Section 6-3
C200HX/HG/HE PLCs
CVM1, and CV-series 
PLCs
CQM1H-series PLCs
Network Status
The nodes on the network are shown in the following illustrations.
C200HX/HG/HE PLCs
CS/CJ-series, CVM1, and 
CV-series PLCs
CQM1H-series PLCs
Name
Operating 
level
Address
Contents
Network Instruction 
Enabled Flag
1
SR 25204
0: Execution not possible (already 
executing)
1: Execution possible (not executing)
0
SR 25201
Network Instruction 
Error Flag
1
SR 25203
0: Normal end
1: Abnormal end
0
SR 25200
Name
Address
Contents
Word
Bit
Network 
Instruction 
Enabled Flag
A502
Port number corresponds 
to bit number, i.e., port 0: 
bit 00, port 1: bit 01, etc.
0: Execution not enabled (executing)
1: Execution enabled (not executing)
Network 
Instruction 
Error Flag
A502
Port number corresponds 
to bit number plus 8, i.e., 
port 0: bit 08, port 1: bit 09, 
etc.
0: Normal end
1: Abnormal end
Name
Address
Contents
Network Instruction 
Enabled Flag
AR 0209
0: Execution not possible (already executing)
1: Execution possible (not executing)
Network Instruction 
Error Flag
AR 0208
0: Normal end
1: Abnormal end
Operating level 0 
AR 08
AR 09
Operating level 1 
AR 12
AR 13
The numbers in the squares indicate node addresses.
The corresponding node participation status is as follows:
0:   Not part of network
1:   Part of network
The numbers in the squares indicate node addresses.
The corresponding node participation status is as follows:
0:   Not part of the network
1:   Part of the network
N: Unit number
CIO 1500 + 25 
×
 N + 2
CIO 1500 + 25 
×
 N + 3
IR 192
IR 193
The numbers in the squares indicate node addresses.
The corresponding node participation status is as follows:
0:   Not part of network
1:   Part of network