Delta Electronics VFD007S23A Manuale Utente

Pagina di 186
Chapter 5 Parameters|VFD-S Series 
5-2
 
Revision August 2006, SE08, SW V2.61
 
5.1 Summary of Parameter Settings 
: The parameter can be set during operation. 
Group 0 User Parameters 
Pr.  
Explanation 
Settings 
Factory 
Setting
NOTE
0-00 
Identity Code of the AC Motor Drive 
Read-only 
d # 
 
0-01 
Rated Current Display of the AC 
Motor Drive 
Read-only d##.# 
 
0-02 
Parameter Reset 
d09: All parameters are reset to 
factory settings (50Hz, 
220V/380V) 
d10: All parameters are reset to 
factory settings (60Hz, 
220V/440V) 
d0  
0-03  Start-up Display Selection 
d0: Display the frequency command 
value (LED F) 
d1: Display the actual output 
frequency (LED H) 
d2: Multifunction display, see Pr.00-
04 
d3: Display output current (LED A) 
d4: Display forward/reverse 
command (Frd/rEv) 
d0 
 
0-04  Content of Multi-Function Display 
d0: Display User-Defined Unit (u) 
d1: Display Counter Value (C) 
d2: Display Process Operation (1.tt)
d3: Display DC-BUS Voltage (
u
d4: Display output voltage (E) 
d5: Display frequency commands of 
PID (P) 
d6: Display analog feedback signal 
value (b) (%) 
d0 
 
0-05  User-Defined Coefficient K 
d0.1 to d160 
d1.0 
 
0-06 
Software Version 
Read-only  
d#.# 
 
0-07 
Password Input 
d0 to d999 
d0 
 
0-08 
Password Set 
d0 to d999 
d0 
 
0-09  Memory Mode Selections 
d0 to d63 
d8 
 
 
Group 1 Basic Parameters 
Pr. Explanation 
Settings 
Factory 
Setting
NOTE
1-00 
Maximum Output Frequency (Fmax) 
d50.0 to d400 Hz 
d60.0 
 
1-01 
Maximum Voltage Frequency (Fbase)  d10.0 to d400 Hz 
d60.0 
 
230V series: d2.0V to d255V 
d220 
 
1-02 
Maximum Output Voltage (Vmax)  
460V series: d4.0V to d510V 
d440 
 
1-03 
Mid-Point Frequency (Fmid) 
d1.0 to d400 Hz 
d1.0 
 
1-04 
Mid-Point Voltage (Vmid) 
230V series: d2.0V to d255V 
d12