Delta Electronics VFD007S23A Manuale Utente

Pagina di 186
Chapter 5 Parameters|VFD-S Series 
5-4
 
Revision August 2006, SE08, SW V2.61
 
Pr. Explanation 
Settings 
Factory 
Setting
NOTE
2-00 
Source of Master Frequency 
Command 
d4: Master Frequency operated by 
RS-485 serial communication 
interface and record frequency 
of power loss. (record the 
frequency of power loss and it 
can do analog overlap plus) 
d5: Master Frequency operated by 
RS-485 serial communication 
interface and won’t record 
frequency before power loss. 
(won’t record the frequency of 
power loss and it can do analog 
overlap plus) 
d0 
 
2-01 
Source of Operation  
Command 
d0: Digital Keypad 
d1: External terminals. Keypad 
STOP/RESET enabled. 
d2: External terminals. Keypad 
STOP/RESET disabled. 
d3: RS-485 serial communication 
(RJ-11) .Keypad STOP/RESET 
enabled. 
d4: RS-485 serial communication 
(RJ-11). Keypad STOP/RESET 
disabled. 
d0 
 
2-02 Stop 
Method 
d0: STOP: ramp to stop; E.F.: coast 
to stop 
d1: STOP: coast to stop; E.F.: coast 
to stop 
d0 
 
2-03 
PWM Carrier Frequency Selections 
d3: 3KHz 
d4: 4KHz 
d5: 5KHz 
d6: 6KHz 
d7: 7KHz 
d8: 8KHz 
d9: 9KHz 
d10: 10KHz 
d10 
 
2-04 
Motor Direction Control 
d0: Enable forward/reverse 
operation 
d1: Disable reverse operation 
d0 
 
2-05 
Loss of ACI Signal 
d0: Decelerate to 0 Hz 
d1: Coast to stop and display “EF” 
d2: Continue operation by last 
frequency command 
d0 
 
2-06 
Analog Auxiliary Frequency Operation
d0: Disable 
d1: Enable + AVI 
d2: Enable + ACI 
d0 
 
 
Group 3 Output Function Parameters