Troubleshooting
Troubleshooting
Problem:
• I joined a network instead of adding another 
controller to my network.  Now, neither the 
software nor the controller can control anything. 
Problem:
• I cannot control a module in my network, or 
am experiencing intermittent module failures or 
sluggishness controlling my modules.
Problem:
• I moved a module, and now I cannot control it.
Solution:
• You have accidentally overwritten your Primary 
Controller with a blank network.  Reset both 
controllers and all modules in your network, and 
set up your network again.
Solution:
• Check to make sure that there is power 
supplied to the device.  
• For plug-in modules, ensure that the outlet 
is not a switched outlet, or that the outlet is 
switched on.
• For modules with no neutral connection (such 
as dimmers), ensure that the attached load 
(such as a light bulb) is not burned out.
• Your computer must be able to communicate 
with the module directly, or must be able to 
communicate by routing messages through 
other modules in your network.  You may need 
to add additional modules to your network 
to provide for reliable communication (in 
between your computer and the sluggish/non-
communicating module).  
• ensure that there are no broken or missing 
modules in your network.  It is possible that the 
network is trying to route messages through 
broken or missing modules, so removing them 
may enhance network performance.  See 
“Removing or replacing broken modules” on 
page 14.
• For best performance, attach the USB 
Z-Wave
®
 adapter to the USB extension cable 
included in this package.  Then, place the USB 
Z-Wave
®
 adapter in an open area away from 
walls or other dense materials or metal.
Solution:
• Switch to the SeTTINGS tab, and click the 
oPTIMIZe AND RePAIR NeTWoRk link.  If you 
are not using Thinkessentials
®
 as your primary 
controller, remove the module from your network 
using the primary controller, add it while it is 
powered in its new location, and then update 
Thinkessentials
®
 using the ReCeIVe UPDATe 
FRoM PRIMARY CoNTRoLLeR feature.