Yamaha AW4416 Manuale Utente

Pagina di 507
SET UP screen
18
        
— Reference Guide
Patch Lib page
Store or recall patching settings
[Function]
Store the settings of the Patch IN/Patch 
OUT pages in the patch library, or recall 
previously-stored settings.
[Key operation]
• [SETUP] key → [F3] (Patch Lib) key 
(*1)
• Repeatedly press the [SETUP] key until 
the display shown at right appears.
*1. In the SET UP screen, the tabs dis-
played at the bottom of the screen are 
divided into two groups. If the Patch 
Lib tab is not assigned to the [F3] key 
when you press the [SETUP] key, press 
[SHIFT] key + [F1] (CHANGE TAB) key 
to switch the tabs.
[Mouse operation]
M button → SETU button → Patch Lib tab
[Screen functions]
A
SEL CH
This indicates the channel currently selected by 
the [SEL] key.
B
INPUT
This indicates the input signal patched to the 
channel shown in 1. Refer to the explanation 
of the Patch IN page for the meaning of each 
abbreviation.
C
BUS
This area shows the buses to which the signal of 
the channel is being sent. For buses 1–8 ( – ) 
and the stereo bus ( ), buses to which that 
channel is assigned will be displayed as white 
characters on black background.
D
TRACK 1-8/9-16
This area displays ■ symbols to indicate the 
track inputs to which buses 1–8 ( – ) and the 
direct output ( ) of the input channel currently 
selected by the [SEL] key are patched.
E
Input meter
This shows the input level of the odd-numbered 
→ even-numbered channels adjacent to the 
channel selected in 1, or the output level of the 
stereo output channel.
F
TITLE EDIT button
Use this button when you wish to edit the name 
(library title) of the patching settings saved in the 
library. Move the cursor to the TITLE EDIT but-
ton and press the [ENTER] key to access the 
TITLE EDIT screen where you can input the 
name.
Library number 0 is a recall-only preset, and 
therefore its name cannot be changed. Patch 
library numbers in which no data has been 
stored will be displayed as “No Data!,” and 
their title cannot be edited.
G
RECALL button
This button recalls the currently selected patch-
ing settings from the list.
If you select a number in which nothing has 
been stored and attempt to recall it, an error 
message of “ERROR NO DATA TO RECALL” 
will be displayed, and the recall will not take 
place.
H
STORE button
Store the current patching settings.
1
2
3 5
6
4
7
8
9
J
K L