Environmental Monitoring of the Power Supply
The environmental monitoring and reporting functions allow you to maintain 
normal system operation by resolving adverse environmental conditions prior to 
loss of operation.
The power supplies monitor their own internal temperature and voltages. In the 
event of excessive internal temperature, the power supply will shut down to 
prevent damage. When the power supply returns to a safe operating temperature, 
it will restart. In the event of an abnormal voltage on one or more outputs of the 
power supplies, the OUTPUT FAIL LED will light. Substantial overvoltage 
conditions can lead to a power supply shutdown.
The power supply front panel LEDs are described in 
For more information about the environmental monitoring feature, refer to the 
Cisco 7600 Series Internet Router Software Configuration Guide.
Table 1-2
Power Supply Front Panel LEDs
LED
Description
INPUT OK
AC-input power supplies:
Green when the input voltage is OK (85 VAC or 
greater)
Off when the input voltage falls below 70 VAC or if the 
power supply shuts down
DC-input power supplies:
Green when the input voltage is OK (–40.5 VDC or 
greater)
Off when the input voltage falls below –33 VDC or if 
the power supply shuts down
FAN OK
Green when the power supply fan is operating properly
OUTPUT FAIL
Red when there is a problem with one or more of the 
DC-output voltages of the power supply