Cisco Systems 7609 Manuale Utente

Pagina di 120
Chapter 3      Installing the Cisco 7609 Internet Router
System Ground Connection
3-12
Cisco 7609 Internet Router Installation Guide
OL-5079-04
System Ground Connection
This section describes how to connect a system (earth) ground to the Cisco 7609 
Internet Router.
Note
You must connect both the system ground connection and the power supply 
ground connection to an earth ground.  The system ground connection is 
required if Foreign Exchange Station (FXS) modules are installed or if this 
equipment is installed in a US or European Central Office.
Two threaded M4 holes are provided on the chassis frame to attach the ground 
cable. (See 
Note
If FXS modules are installed or if this equipment is installed in a US or 
European Central Office, you must use the system (earth) ground on both AC- 
and DC-powered systems.
Required Tools and Equipment
To connect the system ground, you need the following tools and materials:
Note
Materials are not provided; contact any commercial cable vendor for the 
required parts.
Grounding lug
The grounding lug must have two M4 screw holes and accept 6 AWG wire.
Two M4 (metric) hex-head screws with locking washers
One grounding wire
The grounding wire should be sized according to local and national 
installation requirements. The length of the grounding wires depends on the 
proximity of the Cisco 7609 Internet Router to proper grounding facilities.
Number 2 Phillips-head screwdriver
Crimping tool