Chapter 1      Product Overview
Blower Module
1-44
Cisco 12016, Cisco 12416, and Cisco 12816 Router Installation and Configuration Guide
OL-11495-01
Blower Module
The router has two blower modules to distribute air within the chassis. One blower 
module is located above the upper card cage; the second blower module is located 
below the lower card cage (see 
).
Each blower module contains three variable speed fans and a controller card. The 
two front cover LEDs provide a visual indication of blower module status 
(
):
Figure 1-22 Blower Module 
  •
OK (green)—All three fans are operating normally.
  •
FAIL (red)—The system has detected a fan failure or other fault in the blower 
module. The fault can be caused by any of the following:
  –
One or more fans are not operating
  –
One or more fans are running below speed
  –
A controller card fault
The blower modules maintain acceptable operating temperatures for the internal 
components by drawing cool air through a replaceable air filter into the switch 
fabric card cage and then through the upper and lower card cages. 
illustrates the air flow path through the chassis.
129308
LEDs