MAX 6000/3000 Network Configuration Guide
Configuring WAN Access
Configuring inbound calls
3–8 represent expansion slots. When looking at the back panel of the unit, slot 3 is the 
bottom slot in the left bank of slots, followed by 4 and 5 in ascending order. Slot 6 is the 
bottom right slot, followed by 7 and 8 in ascending order. 
9 represents the LAN. The unit routes calls to the bridge/router module.
Note:
When a unit has more than one digital modem slot card installed, the cards and 
modems form a pool, and any modem can answer a call routed to any digital modem slot.
Exclusive port routing
If a call comes in on an ISDN line and the MAX unit finds no explicit call-routing information, 
the unit can route the call by means of bearer service information. By turning on exclusive port 
routing, however, you can prevent the MAX unit from accepting calls for which it has no 
explicit routing destination. 
If you set the System > Sys Config > Excl Routing parameter to No (the default), the unit 
routes the call on the basis of bearer service. It routes voice calls to a digital modem, routes 
V.110 calls to a V.110 module, and routes data calls to an AIM port or, if no AIM ports are 
available, to the bridge/router. If you set Excl Routing to Yes and none of the specified 
call-routing comparisons are successful, the unit drops the call.
Using DNIS-related methods to limit incoming calls
You can limit the number of simultaneous incoming calls that a MAX unit accepts on each of 
up to sixteen dialed numbers. You can also limit incoming calls to calls from modem callers, 
V.110 callers, or HDLC callers. Three terminal-server commands are available to display 
DNIS sessions and statistics.
Overview
You can configure the MAX unit to limit the number of incoming calls on the basis of:
Called number ID (DNIS) presented by calls
MAX resource that answers the call: modem, HDLC, or V.110
Combined maximum number of calls to modem, HDLC, and V.110 resources
Note:
The MAX unit considers a call to be an HDLC call if it is not a modem call or a V.110 
call.
The unit returns the cause Busy for rejected calls. 
If the unit receives a call that does not specify a dialed number or that provides a dialed number 
not specified by the DNIS #N parameters (where N=1 to 16), the unit considers the call as 
having an Unspecified DNIS.
Call routing
When you set Ethernet > Mod Config > DNIS Options > DNIS Limitation to Yes, and the 
MAX unit receives a call that provides a DNIS number specified by Ethernet > Mod Config > 
DNIS Options > DNIS #N, the unit routes the call as follows: