Configuring WAN Access
Configuring inbound calls
MAX 6000/3000 Network Configuration Guide
 3-63
1
The unit compares the value specified for the DNIS #N Max Calls parameter to the 
number of calls that have already dialed the called number and are still active.
If the maximum has been reached, the unit rejects the call.
2
If the call is a modem call, the unit compares the value specified for the DNIS #N Max 
Modem parameter to the number of active modem calls made to the called number.
If the maximum has been reached, the unit rejects the call.
3
If the call is a V.110 call, the unit compares the value specified for the DNIS #N Max V110 
parameter to the number of active V.110 calls made to the called number.
If the maximum has been reached, the unit rejects the call.
4
If the call is not a modem or V.110 call, the unit considers it an HDLC call and compares 
the value specified for the DNIS #N Max HDLC parameter to the number of active HDLC 
calls made to the called number.
If the maximum has been reached, the unit rejects the call.
The unit answers the call if no maximum has been reached.
If the call does not provide DNIS information, or no specified DNIS #N value matches the 
provided DNIS number:
1
The MAX unit compares the value specified for the Unspecified Max Calls parameter to 
the number of unspecified active calls.
If the maximum has been reached, the MAX rejects the call.
2
If the call is a modem call, the unit compares the value specified for the Unspecified Max 
Modem parameter to the number of unspecified active modem calls.
If the maximum has been reached, the unit rejects the call.
3
If the call is a V.110 call, the unit compares the value specified for the Unspecified Max 
V110 parameter to the number of unspecified active V.110 calls.
If the maximum has been reached, the unit rejects the call.
4
If the call is not a modem or V.110 call, the unit considers it an HDLC call and compares 
the value specified for the Unspecified Max HDLC parameter to the number of 
unspecified active HDLC calls.
If the maximum has been reached, the unit rejects the call.
The unit answers the call if no maximum has been reached.
Limiting calls to specific dialed numbers
To limit calls to specific dialed numbers, proceed as follows:
1
Open the Ethernet > Mod Config > DNIS Options profile.
2
Set DNIS Limitation to Yes.
3
Set the DNIS #N parameter to a called number.
The MAX unit compares the called number to the DNIS #N value digit-by-digit, from 
right to left. A match occurs if all the digits specified by DNIS #N match the digits at the 
end of the called number. For example, if you set DNIS #N to 1235, the called number 
8761235 matches, but 8762235 does not match.