Lucent Technologies PortMaster Manuale Utente

Pagina di 364
Using Frame Relay
13-9
Configuration Steps for a Frame Relay Connection
For more information on Ethernet parameters, refer to Chapter 4, “Configuring the 
Ethernet Interface
.”
Configuring Synchronous WAN Port Parameters
Configure the synchronous WAN port W1 to the values shown in Table 13-3.
After you configure the synchronous WAN port as shown in Table 13-3, enter the 
following commands to reset the port and save the configuration:
Command> reset w1
Command> save all
For more information on synchronous ports, refer to Chapter 6, “Configuring a 
Synchronous WAN Port
.”
Configuring the PortMaster in New York
Configure the settings for the PortMaster in New York with the values in the following 
sections. You do not need to specify a gateway for the PortMaster in New York because 
it is on the Internet.
Table 13-3
Synchronous WAN Port Values
Setting
Command
Port type
set w1 network hardwired
Protocol
set w1 protocol frame
Port IP address
set w1 address 192.168.20.1
Netmask
set w1 netmask 255.255.255.0
Modem control
set w1 cd on
RIP routing
set w1 rip broadcast
Annex-D
set w1 annex-d 10
(LMI can be used instead of Annex-D.)
DLCI list
set w1 dlci 16:192.168.20.2
(You do not need to set a DLCI list if the remote router supports 
Inverse ARP.)