Lucent Technologies PortMaster Manuale Utente

Pagina di 364
Configuration Steps for an Office-to-Office Connection
15-4
PortMaster Configuration Guide
Configuring the Office Router in London
Configure the following settings on the PortMaster PCMCIA Office Router in the 
London office to enable London office users to access the main office network in Paris 
on demand.
Configuring Global Settings 
Configure the global settings shown in Table 15-1. The values shown in the table only 
apply to this example. When you are configuring your PortMaster, use values 
appropriate for your network.
After you configure the global settings shown in Table 15-1, enter the following 
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global 
Settings
.”
Configuring Ethernet Interface Settings
Configure the Ethernet settings shown in Table 15-2.
Table 15-1
Global Values
Setting
Command
IP gateway
set gateway 192.168.1.1
System name
set sysname london
Table 15-2
Ethernet Values
Setting
Command
IPX network
set ether0 ipxnet F3
IPX frame type
set ether0 ipxframe ethernet_802.2
IP address
set ether0 address 192.168.200.1
Netmask
set ether0 netmask 255.255.255.0