Troubleshooting Functional Failures in Operation
103
3.13 Communication Failure on High-reliability Function
3.13.1
GSRP Communication Failures
If the communication is not possible in the GSRP configuration, isolate the problem according to the failure analysis 
method shown in the table below.
Table 3-58:  Analysis Method for Communication Failure in GSRP Configuration 
If master/backup is not switched as expected in the GSRP configuration, isolate the problem using the failure analysis 
method shown in the table below.
No.
Troubleshooting Steps and Command
Action
1
On this system and remote system 
constituting a GSRP group, check the status 
of the VLAN group to which the failed 
VLAN belongs using the show gsrp 
command.
Go to No. 2 if one system is master and the other system is non-master.
If either system is Backup (No Neighbor), recover from the communication failure 
between direct links. GSRP Advertise frames may have been discarded by 
filtering, or GSRP Advertise frames may have been discarded through bandwidth 
monitoring, discarding control, or shaper of the QoS control.
See "
" to check for it.
If necessary, change the system that is Backup (No Neighbor) to Master using the 
set gsrp master command.
If both systems are Backup or Backup (Waiting), check to see if the master/backup 
selection method (Selection-Pattern) is the same between the systems.
If both systems are Backup (Lock), reset the lock status of either or both systems.
If both systems are Master, restart either GSRP program using the restart 
gsrp command.
In other cases, temporary status transition is in progress. Wait for a while for the 
communication to recover.
2
Check the status of the VLAN port on this 
system and systems on the communication 
path.
Restore the failed VLAN port on this system or systems on the communication 
path.
If the conditions below are all met, activate the VLAN port using the activate 
command.
• The MAC address table flash method for the current VLAN port is "Reset" 
(determine by using the show gsrp command with "port" parameter 
specified).
Go to No. 3 if there is no failure on the VLAN port of this system or systems on 
the communication path.
3
Check the MAC address table flash method 
(GSRP/Reset/No) to the VLAN port on this
system using the show gsrp command 
with "port" parameter specified.
If the MAC address table flash method is either GSRP or Reset and does not match 
the configuration, correct it using configuration command gsrp 
reset-flash-port and gsrp no-flash-port.
If the MAC address table flash method is either GSRP or Reset and matches the 
configuration, restart the GSRP program on this system with the restart gsrp 
command.
If the MAC address table flash method is No, wait for aging of MAC address table 
on the neighboring system on the communication path.