Troubleshooting Functional Failures in Operation
121
3.20 Problems on Redundant Configuration of Basic 
Switching Unit (BSU) [IP8800/S6700]
3.20.1
Active BSU Switchover Is Disabled
If BSU cannot be switched in the redundant configuration, follow the instruction shown below.
1. Checking log
For the log, see the manual "Message Log Reference."
2. Isolating the problem according to the BSU operation status
Check the BSU operation status by using the show system command, and isolate the problem according to the 
table below.
Table 3-68: Failure Analysis Method When BSU Switchover Disabled
No.
BSU Operation
Status
Problem
Action
1
active (not standby 
hot, standby cold, 
standby cold2)
The number of BSU boards set in 
configuration command redundancy 
max-bsu does not match the number of 
BSU boards which are to be operated as the 
active BSU.
Use configuration command redundancy 
max-bsu to set the number of BSU boards to be 
operated as the active BSU.
BSU boards to be standby BSU are not 
installed.
Install the BSU boards.
2
fault
Unavailable configuration has been set.
Use configuration command fldm prefer to set 
flow distribution pattern of the filter and QoS function 
correctly.
Use configuration command fwdm prefer to 
correctly set the distribution pattern of the maximum 
number of entries per device.
The BSU is faulty.
According to the log of the BSU displayed by the show 
logging command, see the corresponding part in 
manual "Message Log Reference" and follow [Action] 
described.
3
inactive
The inactivate bsu command is set.
Use the activate bsu command to make the BSU 
active, standby hot, standby cold status, or standby cold 
status2.
The setting by Configuration command 
redundancy bsu-load-balancing 
smac or redundancy bsu-mode 
fixed exists.
Delete the setting by Configuration command 
redundancy bsu-load-balancing smac or 
redundancy bsu-mode fixed and restart the 
system. For more details, see the manual 
"Configuration Settings."
The BSU is not fully inserted.
Install the BSU board correctly.
Different types of BSUs are installed 
together.
Unify the type of all BSU boards.
BSU not supported by the software version 
is installed.
Check the BSU board type and software version. 
Replace the BSU board or update the software.
BSU not supported by this device is 
installed.
Replace the BSU board.