Zebra Technologies RZ400 Manuale Utente
63
Operations
Calibrate the Printer
1/11/11
Z Series
®
/RZ™ Series User Guide
79695L-003
Calibrate the Printer
The printer can be set to calibrate automatically, or you can calibrate it manually.
Auto Calibration
When the control panel setting for
MEDIA POWER UP
or
HEAD CLOSE
is set to
CALIBRATION
, the printer automatically calibrates on power up or when the printhead is
closed. During auto calibration, the printer determines the label length and sensor settings. The
results of the auto calibration are stored in the printer’s temporary memory. These parameters
remain in effect until the next calibration is performed or until the printer is power cycled.
results of the auto calibration are stored in the printer’s temporary memory. These parameters
remain in effect until the next calibration is performed or until the printer is power cycled.
Manual Calibration
Perform a media and ribbon sensor calibration to reset the sensitivity of the sensors so the
media and ribbon are detected more accurately. If you change the type of ribbon or media,
your printer may operate better if you perform this calibration.
media and ribbon are detected more accurately. If you change the type of ribbon or media,
your printer may operate better if you perform this calibration.
For instructions, refer to
.
Important •
To retain calibration settings in the printer’s memory when the printer is power
.
Note •
If the control panel settings for
MEDIA POWER UP
or
HEAD CLOSE
are set to
LENGTH, NO MOTION, or FEED, the printer starts printing without auto calibrating. See
or
.