Programming
System Related Commands
10/05/2009
TTP 7030™ Technical Manual
P1003636-002
A number of bytes in the flash PROM hold various parameter values called default 
parameters
. One or several of them can be overridden temporarily with this command. 
The permanently stored parameters will be used again after a printer-reset command or at 
power ON. 
The temporary values can, however, be stored in the flash PROM as permanent values with 
command <ESC>&<4>.
Set several parameters at once
ESC & P <0> <FromPar><ParCount><Data>
FromPar is the parameter number to start writing and ParCount is the number of bytes being 
sent. For every byte sent the parameter number is incremented. 
This command should be used when you integrate firmware loading into your kiosk program. 
This command should only be used when loading new firmware into the printer. See also 
ESC & P n1...n2
Set Parameter Value
1B 26 50 n1...n2
hex
27 38 80 n1...n2
decimal
n1  
Parameter number, range 1 -255.
n2 Parameter 
value. 
Example • 
This example sets the first 5 tabs to 5, 10, 15, 20, and 25. 
(FromPar 15, ParCount 5)
<ESC>&P<0><15><5><5><10><15><20><25>«»
ESC NUL 
Load Firmware
1B 00  
Hex
27 0  
Decimal
Note • 
Utility programs to load firmware into the printer are available from 
http://www.zebra.com
 .