Zebra Technologies 7030 Manuale Utente

Pagina di 128
Programming
Status Reporting Commands
56
P1003636-002
TTP 7030™ Technical Manual
10/05/2009
Status Reporting Commands
See also 
. 
A status enquiry results in response ACK (06h) if all sensors are clear, but NAK (15h) + code if 
one or more sensors report fault condition. 
Note • 
All status commands are immediate, that is they pass the print queue and is answered 
directly.
ESC ENQ 1
Status Enquiry
1B 05 01 
hex
27 5 1 
decimal
Figure 19 • Error Codes
Error code
Meaning
ACK
OK (printer is operable)
NAK 1
Paper left in presenter module. Attempt to clear the paper path failed.*
*. From firmware version 3.00, the printer will retry three times (cut + clear presenter), when failing to clear the 
presenter.
NAK 2
Cutter jammed
NAK 3
Out of paper
NAK 4
Printhead lifted
NAK 5
Paper-feed error. No paper detected in presenter although 10 cm has been 
printed. Paper might be wound around the platen or, in some way, has 
been forced above the presenter module.
NAK 6
Temperature error. The printhead temperature has exceeded the 60 °C 
maximum limit.
NAK 7
Presenter not running (no feedback from code wheel)
NAK 0A
Black mark not found
NAK 0B
Black mark calibration error
NAK 0C
Index error
NAK 0D
Checksum error
NAK 0E
Wrong firmware type
NAK 0F
Firmware cannot start because no firmware is loaded or firmware 
checksum is wrong. 
NAK 10
Waste bin timed out. If the customer doesn’t take the paper and the 
printer clears the presenter due to a timeout, the pending error bit is set 
and error code NAK 16 is reported.
NAK FF
Undefined error