4  Replacement Procedures  
4.22  Microphone 
4.22 Microphone 
Removing the microphone 
The following describes the procedure for removing the microphone (See Figure 4-38). 
1.  Remove the following screw to remove the microphone hold guide from the base 
assembly. 
•  M2×4Z BIND 
screw   x1 
2.  Detach the microphone from the microphone hold guide. 
3.  Detach the microphone cover from the microphone. 
 
M2x4Z  BIND
Microphone 
Microphone cover 
Microphone Hold Guide 
Figure 4-38  Removing the microphone 
Installing the microphone 
The following describes the procedure for installing the microphone (See Figure 4-38). 
1.  Install the microphone cover on the microphone. 
2.  Install the microphone to the microphone hold guide. 
3.  Install the microphone hold guide along the guide and secure it with the following 
screw
•  M2×4Z BIND 
screw   x1 
QOSMIO F10  Maintenance Manual (960-498) 
 