Fujitsu BS2OSD Manuale Utente

Pagina di 47
 
Page 34
 
  *4 
Innovations in IMON V3.0 
 
  *4 
With IMON V3.0, delivery units that are parked on a key-formatted 
  *4 
pubset can be installed on a non-key-formatted pubset.  
 
  *4 
Previously, the statement GENERATE-IDF displayed all delivery  
  *4 
units. Only the installed delivery units are now offered in the  
  *4 
dialog. 
 
  *4 
As of IMON V3.0, the TASKLIB and MACROLIB can also be installed  
  *4 
under a default user ID (DEFLUID system parameter) other than  
  *4 
TSOS. The parameter ZVDEFSUP in the IMON parameter file must be  
  *4 
set to "Y" for this.  
  *4 
Important note: if the parameter ZVDEFSUP is set to "Y", the two  
  *4 
files $TSOS.TASKLIB and $TSOS.MACROLIB must be copied under the  
  *4 
default user ID and deleted from under $TSOS before the next IMON 
  *4 
installation. 
 
  *4 
In addition, IMON V3.0 also contains preliminary functions for  
  *4 
future hardware platforms and BS2000/OSD-BC versions. 
 
 
CRTE-BASYS: 
  *4 
The subsystem CRTEBASY of CRTE-BASYS V1.6 is available as a run- 
time environment for BS2000-internal applications. This subsystem 
should only be preloaded if this is recommended in the Release 
Notice of another installed product. 
By default the subsystem is loaded in upper class 4 memory. As an 
alternative, the subsystem can also be loaded below 16 MB in 
class 4 memory using the SYSSSC file with the extension LOW 
  *4 
(SYSSSC.CRTE-BASYS.016.LOW) if there is enough space available 
there. 
In addition, IMON copies the IC@RTSXS, IC@STLNK and IC@ULINK mod- 
  *4 
ules from the SYSLNK.CRTE-BASYS.016.CLIB library to CLIB. If no 
$.CLIB file exists on the source system it is created by IMON. 
This $.CLIB can be used for programs which were compiled with C 
V2.0 or earlier. 
 
The compatibility library SYSLNK.ILCS is also installed with 
CRTE-BASYS. 
 
If a default user ID other than TSOS is used (DEFLUID system pa-
rameter), it should be noted that during installation of CRTE-
BASYS not all libraries are automatically installed under the de-
fault user ID. When installation with IMON is completed, the 
$TSOS.CLIB file must be copied to $<default_user_ID>.CLIB. 
 
 
3.4  Product use 
 
All conversion activities for BS2000/OSD-BC V6.0 are described in 
the manual BS2000/OSD-BC V6.0 Migration Guide. 
 
An update to BS2000/OSD-BC V6.0 is possible on the basis of 
BS2000 versions OSD-BC V4.0 and V5.0. A first-time installation 
of BS2000/OSD-BC V6.0 must be made for all earlier BS2000 ver-
sions. Configurations with V4.0 and V5.0 are possible with a 
shared pubset network using MSCF.