CyberPower Systems UP825 Manuale Utente

Pagina di 16
 
 
 
BATTERY REPLACEMENT AND STORAGE 
 
Contact your dealer or call the number in this manual for information on battery replacement.   
The order numbers for the battery are as follows:   
BA-UP625 for UP625 
BA-UP825 for UP825 
 
CAUTION!
 Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing 
the battery.    Service the battery under the supervision of personnel knowledgeable of 
batteries and their precautions.    Keep unauthorized personnel away from batteries. 
CAUTION!
 Use only the specified type of battery. See your dealer for replacement 
batteries. 
CAUTION!
 The battery may present the risk of electrical shock. Do not dispose of batteries 
in a fire, as it may explode. Follow all local ordinances regarding proper disposal of 
batteries. 
CAUTION! 
Do not open or mutilate the batteries. Release electrolyte is harmful to the skin 
and eyes and may be toxic.
 
CAUTION! 
A battery can present a high risk of short circuit current and electrical shock. 
Take the following precautions before replacing the battery: 
1. Remove all watches, rings or other metal objects. 
2. Only use tools with insulated handles. 
3. DO NOT lay tools or other metal parts on top of battery or any battery terminals. 
4. Wear rubber gloves and boots. 
5. Determine if the battery is inadvertently grounded. If inadvertently grounded, remove 
source of ground. CONTACT WITH A GROUNDED BATTERY CAN RESULT IN 
ELECTRICAL SHOCK! 
The likelihood of such shock will be reduced if such grounds 
are removed during installation and maintenance (applicable to a UPS and a remote 
battery supply not having a grounded circuit). 
 
BATTERY REPLACEMENT PROCEDURE: 
 
1. Turn off and unplug all connected equipment. 
2. Turn the UPS off and unplug it from the AC power source. 
3. Turn the UPS upside down. 
 
 
 
 
4. Remove the 4 retaining screws and remove the cover. 
 
 
 
 
 
4