4. 
CAUTION!    Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. 
CAUTION - RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING 
TO LOCAL REGULATIONS. 
 
TO REPLACE THE BATTERY 
1.  Turn off and unplug all connected equipment. 
2.  Unplug it from the AC power source. 
3.  Turn the UPS upside down. 
4.  Remove the 1 retaining screw. 
5.  Slide the battery compartment cover completely off of the unit. 
6.  Remove the battery from the compartment. 
7.  Disconnect the battery wires from the battery. 
8.  Install the replacement battery by connecting the red wire and black wire to the positive (+) and negative (-) terminal of the battery. 
9.  Put the battery back into the compartment. 
10.  Slide back the battery compartment cover and tighten the retaining screw. 
11.  Charge the unit for 4 – 8 hours. 
 
REMINDER:  
Batteries are considered HAZARDOUS WASTE and must be disposed of properly.    Most retailers of lead-acid batteries collect 
used batteries for recycling, as required by local regulations. 
 
 
TROUBLE SHOOTING 
 
 
Problem 
Possible Cause 
Solution 
Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit. 
Circuit breaker has tripped 
due to an overload. 
Turn the UPS off and unplug at least one piece of equipment.   
Wait 10 seconds, reset the circuit breaker by depressing the 
button, and then turn the UPS on. 
Battery not fully charged. 
Recharge the battery by leaving the UPS plugged in. 
The UPS does not perform 
expected runtime. 
Battery is worn out. 
Contact CyberPower Systems about replacement batteries at 
tech@cyberpowersystems.com 
The on/off switch is designed 
to prevent damage by rapidly 
turning it off and on. 
Turn the UPS off.    Wait 10 seconds and then turn the UPS on.
The unit is not connected to 
an AC outlet. 
The unit must be connected to a 110/120v 60Hz outlet. 
The battery is worn out. 
Contact CyberPower Systems about replacement batteries at 
tech@cyberpowersystems.com 
The UPS will not turn on. 
 
Mechanical problem. 
Contact CyberPower Systems at 
tech@cyberpowersystems.com 
The USB cable is not 
connected. 
Connect the USB cable to the UPS unit and an open USB port 
on the back of the computer.    You must use the cable that 
came with the unit. 
PowerPanel
®
 Personal Edition is 
inactive (all icons are gray). 
The unit is not providing 
battery power. 
Shutdown your computer and turn the UPS off.    Wait 10 
seconds and turn the UPS back on.    This should reset the unit.
Additional troubleshooting information can be found at 
www.cyberpowersystems.com/support.htm 
 
 
TECHNICAL SPECIFICATIONS 
 
Model 
CP685AVRLCD-G 
CP825AVRLCD-G 
Capacity 
685VA / 390W 
825VA / 450W 
Input Voltage on Utility 
90V to 140V 
Input Frequency 
57 Hz to 63 Hz 
On-Battery Output Voltage 
120Vac ± 5% 
Transfer Time 
4ms Typical 
Max. Load for UPS Outlets (4 Outlets) 
685VA / 390W 
825VA / 450W 
Max. Load for Full-Time Surge Protection outlets (8 Outlets) 
12 Amps 
On-Battery Output Wave Form 
Simulated Sine Wave Form 
Operating Temperature 
+ 32°F to 104° F / 0° C to 40° C 
Operating Relative Humidity 
0 to 90% NON-CONDENSING 
Size (L x W x H) 
11” x 6 5/8” x 3 1/2” / 28cm x 16.9cm x 8.7cm 
Net Weight 
13.3 lbs 
13.8 lbs 
Battery Type 
12V, 8Ah (BP8-12 / BB) 
12V, 9Ah (HR1234W / BB) 
Typical Battery Recharge Time 
8 hours typical from total discharge 
Typical Battery Life 
3 to 6 years, depending on number of discharge/recharge cycles 
Recommended Battery 
Sealed Maintenance Free Lead Acid Battery 
Safety Approvals 
UL1778(UPS), cUL107., FCC/DoC Class B 
 
EXPECTED RUNTIME IN MINUTES 
(Due to the differences in computer components, the runtime will vary.) 
 
Model 
iMac G4 
Desktop PC with LCD 
Monitor 
Desktop PC 
  with 15” Monitor 
Desktop PC 
  with 17” Monitor 
Desktop PC 
  with 21” Monitor 
CP685AVRLCD-G 
70 minutes 
45 minutes 
28 minutes 
22 minutes 
16 minutes 
CP825AVRLCD-G 
85 minutes 
52 minutes 
36 minutes 
28 minutes 
20 minutes 
 
 
CYBERPOWER GREENPOWER UPS TECHNOLOGY 
 
Our new UPS circuit is designed to save energy operating in GreenPower Bypass Mode. 
A traditional UPS circuit with AVR provides normal output voltage through the Relay and AVR transformer. The   
current travels first through the transformer conducting energy and generating heat. This heat creates energy   
dissipation resulting in a "Power Loss" or consumption of utility power and higher utility bills. 
CyberPower's GreenPower Circuit Design is a solution to this "Power Loss." When the Utility Power is operating   
normally, our Green Power UPS works in Bypass Mode. Our GreenPower design conducts power only through   
the relay and still provides normal output voltage. Bypassing the transformer reduces power consumption thereby   
conserving energy and saving money. When the utility power is abnormal the UPS will operate under Battery   
or AVR Mode. Under these conditions, Green Power UPS and a traditional UPS would operate in approximately   
the same manner. 
On average the CyberPower GreenPower Technology will work in its money/energy saving Bypass Mode 88%   
of the time.
 
 
Limited Warranty and Connected Equipment Guarantee 
 
Read the following terms and conditions carefully before using the CyberPower CP685AVRLCD-G / CP825AVRLCD-G (the “Product”). 
By using the Product you consent to be bound by and become a party to the terms and conditions of this Limited Warranty and 
Connected Equipment Guarantee (together referred to as this “Warranty”). If you do not agree to the terms and conditions of this 
Warranty, you should return the Product for a full refund prior to using it. 
 
Who is Providing this Warranty? 
CyberPower Systems (USA), Inc. (“CyberPower”) provides this Limited Warranty. 
 
What Does This Warranty Cover? 
This warranty covers defects in materials and workmanship in the Product under normal use and conditions.  It also covers 
equipment that was connected to the Product and damaged because of the failure of the Product.   
 
What is the Period of Coverage? 
This warranty covers the Product for three years and connected equipment for as long as you own the Product. 
 
Who Is Covered? 
This warranty only covers the original purchaser.    Coverage ends if you sell or otherwise transfer the Product. 
 
How Do You Get Service?
 
1. 
Call us at (877) 297-6937 or write to us at Cyber Power Systems (USA), Inc., 4241 12
th
 Ave. E., STE 400, Shakopee, MN 55379 
or send us an e-mail message at claims@cyberpowersystems.com for instructions. 
2. 
When you contact CyberPower, identify the Product, the Purchase Date, and the item(s) of Connected Equipment. Have 
information on all applicable insurance or other resources of recovery/payment that are available to the Initial Customer and 
Request a Claim Number. 
3. 
You must provide a purchase receipt (or other proof of the original purchase) and provide a description of the defect. 
4. 
Pack and ship the product to CyberPower and, if requested, the item(s) of Connected Equipment, a repair cost estimate for the 
damage to the Connected Equipment, and all claim forms that CyberPower provides to you. Show the Claim Number on the 
shipping label or include it with the product. You must prepay all shipping costs, you are responsible for packaging and 
shipment, and you must pay the cost of the repair estimate.
 
 
How Long Do I Have To Make A Claim?
 
All claims must be made within ten days of the occurrence. 
 
What Will We Do To Correct Problems? 
CyberPower will inspect and examine the Product. 
 
If the Product is defective in material or workmanship, CyberPower will repair or replace it at CyberPower's expense, or, if 
CyberPower is unable to or decides not to repair or replace the Product (if defective) within a reasonable time, CyberPower will refund 
to you the full purchase price you paid for the Product (purchase receipt showing price paid is required). 
 
If it appears that our Product failed to protect any equipment plugged into it, we will also send you forms for making your claim for the 
connected equipment.    We will repair or replace the equipment that was damaged because of the failure of our Product or pay you 
the fair market value (NOT REPLACEMENT COST) of the equipment at of the time of the damage.    We will use Orion Blue Book, or 
another a third-party valuation guide, or eBay, craigslist, or other source to establish that amount.    Our maximum liability is limited to 
$125,000 for the CP685AVRLCD-G and $200,000 for the CP825AVRLCD-G. 
 
Who Pays For Shipping? 
We pay when we send items to you; you pay when you send items to us. 
 
What Are Some Things This Warranty Does Not Cover? 
1. 
This Warranty does not cover any software that was damaged or needs to be replaced due to the failure of the Product or any 
data that is lost as a result of the failure or the restoration of data or records, or the reinstallation of software.
 
2. 
This Warranty does not cover or apply to: misuse, modification, operation or storage outside environmental limits of the Product 
or the equipment connected to it, nor for damage while in transit or in storage, nor if there has been improper operation or 
maintenance, or use with items not designed or intended for use with the Product, such as laser printers, appliances, aquariums, 
medical or life support devices, etc. 
 
 
What Other Limitations Apply?
 
1. 
This Warranty does not apply unless the Product and the equipment that was connected to it were connected to properly wired 
and grounded outlets (including compliance with electrical and safety codes of the most current electrical code), without the use 
of any adapters or other connectors. 
2. 
The Product must have been plugged directly into the power source and the equipment connected to the Product must be 
directly connected to the Product and not “daisy-chained” together in serial fashion with any extension cords, another Product 
or device similar to the Product, surge suppressor, or power tap.    Any such installation voids the Limited Warranty. 
3. 
The Product and equipment connected to it must have been used properly in a suitable and proper environment and in 
conformance with any license, instruction manual, or warnings provided with the Product and the equipment connected to it. 
4. 
The Product must have been used at all times within the limitations on the Product’s VA capacity. 
 
What are the Limitations?
 
The sole and exclusive remedies of the Initial Customer are those provided by this Warranty. 
 
The Product was designed to eliminate disrupting and damaging effects of momentary (less than 1ms) voltage spikes or impulses 
from lightning or other power transients.    If it can be shown that a voltage spike lasting longer than 1ms has occurred, the occurrence 
will be deemed outside the rated capabilities of the Product and the Limited Warranty is void. CyberPower Does Not Cover or 
Undertake Any Liability in Any Event for Any of the Following: 
 
1. 
Loss of or damage to data, records, or software or the restoration of data or records, or the reinstallation of software. 
2. 
Damage from causes other than AC Power Line Transients, spikes, or surges on properly installed, grounded and 
code-compliant 120 volt power lines in the United States and Canada; transients, surges or spikes on standard telephone land 
lines, PBX telephone equipment lines or Base 10T Ethernet lines, when properly installed and connected. (This exclusion 
applies, for example, to fluctuations in data transmission or reception, by CATV or RF transmission or fluctuations, or by 
transients in such transmission.) 
3. 
Damage from any circumstance described as excluded above with respect to the Product. 
4. 
Damages from fire, flood, wind, rain, rising water, leakage or breakage of plumbing, abuse, misuse or alteration of either the 
product or the Connected Equipment. 
5. 
CyberPower excludes any liability for personal injury under the Limited Warranty and Connected Equipment Guarantee. 
CyberPower excludes any liability for direct, indirect, special, incidental or consequential damages, whether for damage to or 
loss of property [EXCEPT FOR (AND ONLY FOR) the specific limited agreement of CyberPower to provide certain warranty 
benefits regarding "Connected Equipment" under this Warranty], loss of profits, business interruption, or loss of information or 
data. NOTE: Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages, so the 
above limitation may not apply to you. 
6. 
The Product is not for use in high-risk activities or with aquariums. The Product is not designed or intended for use in hazardous 
environments requiring fail-safe performance, or for use in any circumstance in which the failure of the Product could lead 
directly to death, personal injury, or severe physical or property damage, or that would affect operation or safety of any medical 
or life support device (collectively, "High Risk Activities"). CyberPower expressly disclaims any express or implied warranty of 
fitness for High Risk Activities or with aquariums. CyberPower does not authorize use of any Product in any High Risk Activities 
or with Aquariums. ANY SUCH USE IS IMPROPER AND IS A MISUSE OF THE PRODUCT
 
What is the Fine Print? 
 
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. 
 
CyberPower is the warrantor under this Limited Warranty. 
 
For further information please feel free to contact CyberPower at Cyber Power Systems (USA), Inc. 4241 12
th
 Ave E., STE 400, 
Shakopee, MN 55379; call us at (877) 297-6937; or send us an e-mail message at claims@cyberpowersystems.com.