Xantrex Technology XDL 35-5TP Manuale Utente

Pagina di 180
  
Store Settings 
The instrument can store 10 set-ups for each output in non-volatile memory; the parameters 
stored are range, voltage, current limit, OVP and OCP.   The output state and remote sense 
setting are not stored. 
To store a set-up press SHIFT, STORE, store no., OK; the store no. is any key 0 to 9. 
After key-presses SHIFT, STORE, the display shows   
StorE -  
; the SHIFT function is 
cancelled (the light goes off).  At this point, pressing any number key will display that number in 
place of the  
  and show either   
E
   (store Empty) or   
 (store Full) beside it,  
e.g.  
StorE 1.E
StorE 2.F 
.   Any number of stores can be checked by pressing one 
number after another (i.e. without having to press SHIFT, STORE each time) before the selection 
is confirmed with the OK key.  A full store can be overwritten with new settings.  At any time 
before the OK key is pressed the store function can be exited without saving a set-up by pressing 
ESCAPE or by waiting 10 seconds from the last key entry.   
Deleting Stored Settings 
Any store can be returned to 'empty' as follows: select the store by pressing SHIFT, STORE, 
store no.; at that point press  
 .  The display now shows   
dELEt  
in place of   
StorE 
,  e.g.   
dELEt 2.F 
;  pressing OK deletes the content of the store. 
Recall Settings 
To recall a set-up press SHIFT, RECALL, store no., OK; the store no. is any key 0 to 9.  After  
key-presses SHIFT, RECALL, the display shows  
rECAL – 
;  the SHIFT function is cancelled 
(the light goes off).  At this point, pressing any key 0 to 9 will preview the voltage and current 
settings of that store number; the settings flash to indicate preview mode. 
Any number of stores can be previewed by pressing one number after another (i.e. without having 
to press SHIFT, RECALL each time) before the selection is confirmed with the OK key.  Empty 
stores are indicated by flashing  
– 
 in every digit position.  At any time before the OK key is 
pressed the Recall function can be exited without recalling a set-up by pressing ESCAPE or by 
waiting 10 seconds from the last key entry. 
Settings may be recalled with the output on or off.  However, if the recalled setting involves a 
range change the output is turned off to avoid any 'glitches'.  After pressing SHIFT, RECALL, 
store no.,  the ON/OFF key will flash (as well as the OK key) if completing the recall involves a 
range change.  The output may be turned off with the ON/OFF key and the recall then completed 
by pressing OK, or OK may be pressed directly in which case the output is automatically turned 
off and the recall completed. 
Extra Functions 
Variations on some of the factory default functions can be set by the user by using the # extra 
functions facility.  Each function change, detailed in the list below is accessed by pressing SHIFT, 
#, nn, when nn is the 2-digit number in the list below
the display changes to  
HASH No.
_ 
after  
SHIFT, # and the buzzer gives a confirmation beep when the 2-digit number entry is complete.  
As indicated in the opening paragraph of this section, the # functions can be set independently 
(i.e. differently) for each main output; note, however, that the #02, #03 and #21 functions which 
apply to the Auxiliary  Output can only be set when CONTROLis assigned to Output 1. 
# Code 
Function 
00  
Main Output always off at power-up (factory default) 
01 
Main Output status at power-up the same as at last power-down 
02 
Aux Output always off at power up (factory default).   
Set with control assigned to Output 1. 
03 
Aux Output status at power up the same as at last power down. 
Set with control assigned to Output 1. 
 22