Panasonic PT-DZ570E Manuale Utente

Pagina di 96
Monitor Lamp indicators
ENGLISH - 
77
Maintenance
 
J
TEMP indicator
Lamp 
indication
Information
Check point
Remedial measure
Lighting in red
Warm-up status
Did you turn on the power when 
 
z
the ambient temperature was 
lower than approx. 0 °C (32 °F)?
Wait about 5 minutes in the current 
 
z
status.
Install the unit in a location having 
 
z
an ambient temperature from 0 °C 
(32 °F) - 45 °C (113 °F).
High temperature 
inside. (WARNING)
Check the ventilation port is 
 
z
blocked.
Is the room air temperature too 
 
z
high?
Is the filter indicator lighted? 
 
z
Remove the object that is blocking 
 
z
the ventilation port.
Move the projector to a temperature 
 
z
of 0 °C (32 °F) - 45 °C (113 °F) and 
the humidity of 20 % to 80 % (no 
condensation).
Turn off the MAIN POWER switch 
 
z
using the procedure on page 34 and 
replace the ACF unit.
Blinking in red  
(once)
High temperature 
inside.  
(Standby condition)
Blinking in red  
(twice)
High temperature 
inside.  
(Power ON condition)
Blinking in red  
(3 times)
Cooling fan has 
been stopped.
Turn off the MAIN POWER switch 
 
z
using the procedure on page 34 and 
consult the dealer.
Note
If no problem is found or the problem remains, do not turn on the projector. Instead contact your dealer.
 