Galil DMC-1400 Manuale Utente
192 ● TC
DMC-1400 Series Command Reference
ECAM
28
S operand not valid
105
EB1 command must be given first
29
Not valid during coordinated move
110
No hall effect sensors detected
30
Sequence segment too short
111
Must be made brushless by BA
command
command
31
Total move distance in a sequence > 2
billion
billion
112
BZ command timeout
32
More than 511 segments in a sequence
113
No movement in BZ command
33
VP or CR commands cannot be mixed
with LI commands
with LI commands
114
BZ command runaway
41
Contouring record range error
118
Controller has GL1600 not GL1800
42
Contour data being sent too slowly 120 Bad
Ethernet
transmit
46
Gear axis both master and follower
121
Bad Ethernet packet received
50
Not enough fields
122
Ethernet input buffer overrun
51
Question mark not valid
123
TCP lost sync
52
Missing " or string too long
124
Ethernet handle already in use
53
Error in {}
125
No ARP response from IP address
54
Question mark part of string 126
Closed
Ethernet
handle
55
Missing [ or []
127
Illegal Modbus function code
56
Array index invalid or out of range
128
IP Address not valid
57
Bad function or array
130
Illegal IOC Command
58
Not a valid Command Operand
(i.e._GNX)
(i.e._GNX)
131
Serial Port Handshake timeout
59 Mismatched
parentheses
USAGE:
While Moving
Yes
Default Value
---
In a Program
Yes
Default Format
3.0
Command Line
Yes
Can be Interrogated
Yes
Used as an Operand
Yes
Controller Usage
ALL
OPERAND USAGE:
_TC contains the value of the error code.
EXAMPLES:
:GF32 Bad
command
?TC
Tell error code
1 Unrecognized
command