Configuring PVPCs
 
166
Avidia System Configuration and Management User Manual
Adding a Backup PVPC to an Existing Cell Channel Card PVPC 
You can configure backup PVPCs at the same time you configure a primary PVPC, as described 
in the previous section. However, you can also add a backup PVPC to an existing primary PVPC 
configuration.
From the 
::
pvpc
=>
 prompt, type the backup command in the following format:
backup <index> [<lport> <vpi>]
Parameters
<index>
The PVPC Table row index number of the primary PVPC for which you want to configure 
a backup PVPC.
[<lport> <vpi>]
(Optional) Configures a backup PVPC using the specified destination port (format 
slot.port), and VPI. Use the line card port (format slot.port) for the destination port. The 
VPI value can either be the same value as the primary PVPC or a different value. Omitting 
this parameter automatically establishes a backup PVPC on the other line card using the 
same VPI as the primary PVPC.
Examples
::pvpc=> backup 3 12.1 25
::pvpc=> backup 3
Restoring Service from a Backup PVPC to a Primary Cell Channel Card 
PVPC 
After traffic has switched from a primary PVPC to the configured backup PVPC, you can 
manually switch it back. 
1
From the 
::pvpc=>
 prompt, type 
show
 to display the configured cell channel card 
PVPCs.
2
Note the PVPC table index number of the PVPC for which you want to restore service.
3
From the 
::pvpc=>
 prompt, type the restore command in the following format:
restore <index>