Chapter 9: Configuring Frame Relay Interworking
Avidia System Configuration and Management User Manual
211
C
ONFIGURING
 F
RAME
 R
ELAY
 FRF.8 C
IRCUITS
FRF.8 defines how frames are translated between ATM and frame devices.
You configure frame relay FRF.8 circuit parameters from the 
::frf8=>
 prompt. From the 
::root=>
 prompt, type the following command then press 
 to display the 
::frf8=>
 
prompt.
configuration frame-relay frf8
Status Box
Description
Link
The channel card slot and port (format slot.port).
State
The LMI (Local Management Interface) type, which 
defines a method of exchanging status information 
between the customer device and the network. The 
options are:
LMI—LMI Rev-1
ANNEXA—ITU 0.933 Annex-A
ANNEXD—ANSI T1 617 Annex-D
NONE—no LMI support
If the LMI type is set to NONE, the poll interval, inquiry 
interval, error threshold, and monitor events 
parameters are not used.
PollInt
The poll interval value, which is the number of seconds 
between LMI status inquiry messages (range: 5-30). 
FullEnqInt
The enquiry interval value, which is the number of poll 
intervals before a full status inquiry message is sent 
(range: 1-255).
ErrThreshold
The error threshold value, which is the number of 
consecutive poll intervals in which the LMI status 
inquiry messages are not received that are required for 
the link to be declared down (range: 1-10).
MonEvents
The monitor events value, which is the number of poll 
intervals in which the LMI status inquiry messages are 
not received that are required for the link to be 
declared down (range: 1-10).
ENTER