Chapter 9: Configuring Frame Relay Interworking
Avidia System Configuration and Management User Manual
215
Modifying Frame Relay FRF.8 Circuit Parameters
You can modify a subset of the parameters that you configured when creating the frame relay 
circuit. 
1
From the 
::frf8=>
 prompt, type 
show
 then press 
 to display the configured 
circuits.
2
Note the index number of the frame relay FRF.8 circuit configuration you want to modify.
3
From the 
::frf8=>
 prompt, type the set command in the following format then press 
set <index> [-admin (up|down)] [-lpmode (1|2)]
[-lpvalue (0|1)] [-cimode (1|2)] [-demode (1|2)]
[-devalue (0|1)] [-CIR <value>] [-Be <value>] [-Bc <value>]
Parameters
<index>
The index number of the frame relay FRF.8 circuit you want to modify.
[-admin (up|down)]
The administrative status of the line. 
up
 activates the port, 
down
 deactivates the port.
[-lpmode
 
(
1
|
2
)]
The LP mode determines the content of the ATM CLP field when translating from frame 
relay to ATM.
1
—The frame relay header DE field is mapped into the ATM CLP field of every ATM cell 
generated by the segmentation process of the AAL5 PDU containing the information for 
that frame.
2
—The ATM CLP field of every ATM cell generated by the segmentation process of the 
AAL5 PDU containing the information of that frame is set to the LP value.
[-lpvalue (0|1)]
The LP Value determines the content of the ATM cell CLP field when the LP mode is set 
to
2
.
0
—The network cannot discard cells.
1
—The network can discard cells.