ADC SWD4573I1 Manuale Utente

Pagina di 658
 
Chapter 16: Monitoring System Alarms and Status
Avidia System Configuration and Management User Manual
339
M
ONITORING
 S
YSTEM
 H
ARDWARE
 S
TATUS
You monitor system status information, such as fuse and power alarms, and whether a critical, 
major or minor alarm condition exists. From the 
::root=>
 prompt, type the following 
command then press 
.
display hardware system
A screen similar to the following displays.
The following table describes the system status information that displays when you type the 
display hardware system command.
Information
Description
Power
Chassis power supply status. Options:
Unknown
Unknown power supply status.
Failure
One or both power supplies has failed.
OK
Both power supplies are operational.
Fan
Chassis fan status. Options:
Unknown
Unknown fan status or no fans exist.
Failure
One of the fans has failed.
OK
All fans are operational.
Hightemp
The chassis temperature is higher than the range 
required for operation.
CRT
Chassis critical alarm LED status. Indicates whether a critical alarm 
condition exists. Displays either OFF or ON.
MAJ
Chassis major alarm LED status. Indicates whether a major alarm 
condition exists. Displays either OFF or ON.
ENTER
::hardware=> system
Power Fan CRT MAJ MIN AUD FAN1 FAN2 FAN3 FAN4 PWR_MIN IP1
IP2
FU1
FU2
OK
OK
OFF OFF OFF ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
Port
Card Description
Most_Serious_Alarm
Severity
1
Avidia Management Card
PSFailureAlarm
Critical