ADC SWD4573I1 Manuale Utente

Pagina di 658
 
Chapter 20: Configuring Subscriber Services
Avidia System Configuration and Management User Manual
409
The 
IDSL Alarm Profile Table
 window displays the configured IDSL alarm profiles. Click 
 and 
 if necessary to view the entire table. 
 displays the beginning of the table. 
 displays 
the next page of the table.
Adding IDSL Alarm Profiles
You add IDSL Alarm profiles from the 
IDSL Alarm Profile Table
 window.
1
In the 
Hourly ES
 box, type the errored second threshold in seconds, or type 
0
 to disable this 
trap. The range is 0 to 255, with 40 as the default.
The Hourly ES Threshold is the number of errored seconds that must be met or exceeded 
on the IDSL line within an hour for an alarm to display. An errored second generates when 
one or more block errors (CRC violations) are detected during a one second interval.
2
In the 
Hourly SES
 box, type the desired severely errored second threshold in seconds, or 
type
0
 to disable this trap. The range is 0 to 127, with 10 as the default.
The Hourly SES Threshold is the number of severely errored seconds that must be met or 
exceeded on the IDSL line within an hour for an alarm to display. A severely errored second 
generates when the number of block errors (CRC violations) defined by the SES threshold 
parameter (see 
) are detected during a one 
second interval.
3
In the 
Daily ES
 box, type the desired errored second threshold in seconds, or type 
0
 to disable 
this trap. The range is 0 to 4095, with 100 as the default.
The Daily ES Threshold is the number of errored seconds that must be met or exceeded on 
the IDSL line within a day for an alarm to display. An errored second generates when one 
or more block errors (CRC violations) are detected during a one second interval.