ADC SWD4573I1 Manuale Utente

Pagina di 658
 
Chapter 28: Monitoring System Alarms and Status
Avidia System Configuration and Management User Manual
553
The 
SDSL Cell Alarm Status
 window displays the alarm status for the current 15-minute data 
collection interval. The current alarm status displays for both the 
Network
 (upstream) and 
Customer
 (downstream) traffic.
M
ONITORING
 IDSL A
LARM
 S
TATUS
The 
IDSL Alarm Status
 window displays a summary of the alarm data for a specified IDSL line 
and port.
1
Do one of the following:
In the 
Site Map Navigation
 window, click 
IDSL Alarm Status
.
In the 
Tree Navigation
 window, click 
Alarm
IDSL Alarm Status
.
The 
IDSL Alarm Status - Slot/Port Selection
 window displays.
Information Description
Card Description
Slot
Port
The slot, port and description of the card for which 
the alarm information is displayed.
Loss of Signal Seconds (LOSS)
Loss of signal seconds are seconds during which 
the SDSL cell line is incapable of transmitting or 
receiving data and all data is lost. 
Loss of Cell Delineation (LOCD)
Loss of cell delineation seconds are seconds in 
which some cells transmitted during that second 
were lost
.
Severe Loss of Cell Delineation (SLOCD)
Severe loss of cell delineation seconds are seconds 
in which the total number of LOCD events in that 
second exceed 50% of the total bandwidth available 
during that second. During a severe loss of cell 
delineation second most of the cells transmitted 
during that second are lost. 
SNR
SNR margin is a measure of signal quality 
indicating how much margin can be dropped before 
the number of bit errors exceeds the ratio of 1x10-7 
errored bits per bits transmitted
Last Time Alarm Status Changed
The last time the status of an alarm changed.