3-5-4. Simple Counter 
 The  function  of  Simple  Counter  collects  any  information  and  provides  the 
counting about the traffic of the port, no matter the packet is good or bad.  
In the Fig. 3-13, the window can show all ports’ counter information at the same 
time. Each data field has 20-digit long. If the counting is overflow, the counter will be 
reset and restart counting. The data is updated every time interval defined by the 
user. The valid range is 3 to 10 seconds. The Refresh Interval is used to set the 
update frequency. Default update time is 3 seconds.  
 
Function name: 
Simple Counter 
Function description: 
Display the summary counting of each port’s traffic, including Tx Byte, Rx Byte, 
Tx Packet, Rx Packet, Tx Collision and Rx Error Packet. 
 
Fig. 3-16 
 
Parameters description: 
Tx Byte: 
Total transmitted bytes. 
Rx Byte: 
Total received bytes.  
Tx Packet: 
The counting number of the packet transmitted. 
Rx Packet: 
The counting number of the packet received. 
Tx Collision: 
Number of collisions transmitting frames experienced.
 
Rx Error Packet: 
Number of bad packets received.