3-5-5. Detail Counter 
The  function  of  Detail  Counter  collects  any  information  and  provides  the 
counting about the traffic of the port, no matter the packet is good or bad.  
In  the  Fig.  3-14,  the  window  can  show  only  one  port  counter  information  at 
the  same  time.  To  see  another  port’s  counter,  you  have  to  pull  down  the  list  of 
Select, then you will see the figures displayed about the port you had chosen.  
Each data field has 20-digit long. If the counting is overflow, the counter will be reset 
and restart counting. The data is updated every time interval defined by the user. 
The valid range is 3 to 10 seconds. The Refresh Interval is used to set the update 
frequency. Default update time is 3 seconds.  
 
Function name: 
Detail Counter  
Function description: 
Display  the  detailed  counting  number  of  each  port’s  traffic.  In  the  Fig.  3-14,  the 
window can show all counter information of each port at one time
 
 
Fig. 3-17 
Parameter description: 
Rx Packets: 
The counting number of the packet received. 
Rx Octets: 
Total received bytes.