The Pinging Device test is an ICMP (Internet Control Message Protocol) ping test.  
In addition to indicating either “Passed” or “Failed,” the test displays the round-trip 
time of the ping, for example, <10 ms; and  Packet Loss expressed as a percent of 
data lost. 
 
A long ping round trip time, for example, >50 ms and/or any packet loss indicates 
a slow network that is not optimized. 
 
If the Pinging Device Test fails a <Details> button will appear just above the 
<Resource Test> button.  If this is the case, click the <Details> button to 
obtain possible causes and possible solutions. 
 
The result of the TCP (Transmission Control Protocol) test will be either 
passed or failed.  If the TCP test failed a <Details> button will appear just above 
the <Resource Test> button.  If this is the case, click the <Details> button to 
obtain possible causes and possible solutions.   
 
e.  Upon completion of the TCP/IP test, click the <Resource Test> button.  The 
Resource Test consists of two components: Resource Tests and Performance Tests
 
The Resource Test performs a quick communications check.  If the host PC can 
communicate with the device a message that the test passed is displayed. 
 
The Performance Tests obtain quantitative results using the current 
configuration of the acquisition device.  The test results represent the maximum 
rates at which various operations can be performed, and will vary according to 
port hardware capabilities. 
The ADC FIFO Input Speed part of the test results in a display of the maximum 
rate at which data can be transferred from the tested device’s internal ADC FIFO 
to computer memory.  Results are given in samples/second, where a sample  
(2 bytes in length) represents a single A/D value. 
 
 
When testing a DaqLab/2000 Series or a DaqScan/2000 Series device, if 
the unit does not respond within 30 seconds perform the following steps: 
1)   reboot the system 
2)   upon power-up, re-open the Daq Configuration
 applet 
3)   select another configuration setting 
4)   reinitiate the test 
 
This completes the procedure for connecting a DaqLab/2000 Series or a DaqScan/2000 Series 
device to the Ethernet.  
 
 
Reference Notes
Depending on your application and system setup, related information can be found 
in the following sources: 
¾  The DBK Options Manual (p/n 457-0905). 
¾  The Programmer’s Manual, (p/n 1008-0901). 
 
 
Note:  You can access PDF documents directly from the opening screen of the data acquisition 
CD via the <View PDFs> button. 
 
6-12       Configuring the System for Operation                            
898195  
DaqLab/2000 Series & DaqScan/2000 Series