Managing Ethernet MicroLAN Modules
5-22
Alarm Limits
within:
This field displays the user-configurable alarm limit timer interval: the amount of time the 
selected statistics will be counted before being compared to the configured thresholds. The 
allowable values are 10 seconds to 23 hrs/59 mins/59 secs.
Configuring Alarms
You configure alarms by choosing the alarm you wish to enable, setting the threshold to 
the desired level, and selecting a time interval within which that threshold must occur. 
You can base the alarms on: 
Number of collisions per good packet
Number of total packets
Number of broadcast packets
Percentage of error packets
You can also configure board or port alarm limits so that the board or port will be disabled 
when an alarm limit is reached.
Setting the Alarm Limits Time Interval
To set the time interval within which the defined alarm thresholds must be reached in 
order to trigger an alarm:
1.
Click on the clock symbol 
 next to the within: text box in any one of the 
alarm limits windows; the interval you set applies to all configured alarms at all 
levels. The Alarm Interval window
, will appear.
Figure 5-9. The Alarm Interval Window
2.
Highlight the hour text box (the first box to the left).
NOTE
For more detailed definitions of these statistics and information on the possible network 
conditions they represent, consult the 
Enterasys Network Troubleshooting Guide
included with this package.