Alarm Limits
5-23
Managing Ethernet MicroLAN Modules
3.
Click on the up and down arrows to change the time, or type in the new hour 
time interval.
4.
Repeat steps 2 and 3 to set the minutes and seconds of your new time 
interval. Remember, valid settings range from 10 seconds to 23 hours 59 
minutes 59 seconds.
5.
Click on the OK button. The new Alarm Interval you have set will appear in the 
within: text box.
6.
Click on the Apply button at the bottom of the Alarm Limits window to save 
your changes, then click on the Cancel button to close the window. Be sure to 
click on the Apply button before closing the window, or your changes will not 
be saved.
Setting Alarm Limits
To set repeater-, board-, or port-level alarms, first be sure you have opened the appropriate 
Alarm Limits window, then follow the steps outlined below:
1.
Using the mouse, click and drag to highlight the text box in the alarm field you 
wish to configure (CollisionsPacketsBroadcast Packets, or % Errors).
2.
Enter the desired threshold value, being sure to keep in mind the units and 
range limits described above.
3.
Click on the Enable Alarm check box to activate it. (A check box is activated 
if there is an check in it.)
4.
For board- or port-level alarms only, click on the Allow Board/Port to be 
Disabled on Alarm
 check box if you wish to disable the board or port when 
an alarm condition occurs.
5.
Repeat steps 1-4 for each type of alarm you wish to configure.
6.
Click on the Apply button to save the configuration, then click the Cancel 
button to close the window. Be sure to click on the Apply button before 
closing the window, or your changes will not be saved.
NOTES
If you activate the Allow Board/Port to be Disabled on Alarm option, you will have to 
manually re-enable the board(s) or port(s) if the alarm is triggered. Resetting the device 
will clear the condition by clearing all packet counters, but you will still need to re-enable 
the board(s) and/or port(s).
Remember, too, that on an Ethernet MicroLAN module, a board is equivalent to a 
repeater channel; use care when selecting the Allow Board to be Disabled on Alarm 
option.