Avaya P130 Manuale Utente
Chapter 6 Avaya P130 CLI
74
Avaya P130 User’s Guide
Example:
To set port 2 on module 1 to full duplex:
P130-1# set port duplex 1/2 full
Port 1/2 set to full-duplex.
P130-1#
P130-1# set port duplex 1/2 full
Port 1/2 set to full-duplex.
P130-1#
Set port flowcontrol Command
Use the s
et port flowcontrol command to set the send/receive flow-control
frames (whether proprietary or IEEE 802.3x) for a full duplex module port. Each
direction can be configured separately.
This command is supported on Fast and Gigabit Ethernet switching ports.
direction can be configured separately.
This command is supported on Fast and Gigabit Ethernet switching ports.
The syntax for this command is:
set port flowcontrol {receive | send | all}<mod_num/
port_num>{off | on | prop}
set port flowcontrol {receive | send | all}<mod_num/
port_num>{off | on | prop}
receive
Indicates whether the port can receive administrative status
from a remote device. Available only for Gigabit Ethernet
modules with negotiation set to off.
from a remote device. Available only for Gigabit Ethernet
modules with negotiation set to off.
send
Indicate whether the local port can send administrative status
to a remote device. Available only for Gigabit Ethernet
modules with negotiation set to off.
to a remote device. Available only for Gigabit Ethernet
modules with negotiation set to off.
all
Send and receive (symmetric flow control).
mod_num
Module number
port_num
Number of the port on the module
off
Used with receive to turn off an attached device's ability to
send flow-control packets to a local port. Used with send to
turn off the local port's ability to send administrative status to a
remote device.
send flow-control packets to a local port. Used with send to
turn off the local port's ability to send administrative status to a
remote device.
on
Used with receive to require that a local port receive
administrative status from a remote device. Used with send,
the local port sends administrative status to a remote device.
administrative status from a remote device. Used with send,
the local port sends administrative status to a remote device.
prop