Lucent Technologies P332MF Manuale Utente

Pagina di 134
Chapter 4
Installation and Setup
Cajun 
P332MF 
User’s Guide
21
Installing Expansion Sub-modules
Caution:  The expansion sub-modules contain components sensitive to electrostatic 
discharge. Do not touch the circuit board unless instructed to do so.
Installing the Expansion Sub-module into the Cajun P330
1
Remove the blanking plate or other sub-module (if installed).
2
Insert the sub-module gently into the slot, ensuring that the Printed Circuit 
Board (PCB) is aligned with the guide rails.
The PCB not the metal base plate fits into the guide rail.
3
Firmly press the sub-module until it is completely inserted into the Cajun P330.
4
Gently tighten the two screws on the front panel of the expansion sub-module 
by turning them.
Removing an Existing Expansion Sub-module
1
Loosen the screws by turning the knobs.
2
Take hold of the two knobs (one near each side of the front panel) and pull 
gently but firmly towards yourself.
3
Insert another expansion sub-module or the blanking plate.
Note:  The Cajun P330 switch must not be operated with the expansion slot open; 
the expansion sub-module slot should be covered with the supplied blanking plate 
if necessary.
Note:  Expansion sub-modules are hot-swappable and can be inserted or removed 
in an operating base unit.