Cabling
Cajun P330 modules include the following types of ports (according to the speed 
and standard they support): 10Base-T, 100Base-TX, 100Base-FX, 1000Base-SX and 
1000Base-LX. 
Note:  To interconnect Cajun P330 switches with twisted pairs, crossed cables are 
required.
The maximum UTP cable length connected to a 10/100 Mbps port operating as 
10Base-T, is 100 m (328 ft.).
A UTP Category 5 cable must be connected to any 100Base-TX port, via an 
RJ45 connector. The maximum UTP cable length connected to a 10/100 Mbps 
port operating as 100Base-TX, is 100 m (328 ft.).
A fiberoptic cable must be connected to any 100Base-FX port, via a pair of SC 
connectors. The maximum fiber cable length connected to a 100Base-FX port is 
412 m (1,352 ft) when operating in half duplex, and 2 km (6,562 ft) when 
operating in full duplex.
The maximum length of fiber optic cable connected to a 12 fiber MT-RJ port is 
2 km (6,562 ft).
Appropriate cables are available from your local supplier. 
*1000BASE-LX over Multimode fiber requires a special Patch cord cable which you 
can obtain from your local cable supplier.
Table 4.3
Gigabit Ethernet Cabling
Gigabit Interface
Fiber Type
Diameter 
(
mm)
Modal 
Bandwidth
Maximum 
Distance (m)
1000BASE-SX
MM
62.5
160
220
1000BASE-SX
MM
62.5
200
275
1000BASE-SX
MM
50
400
500
1000BASE-SX
MM
50
500
550
1000BASE-LX
MM
62.5
500
550
1000BASE-LX
MM
50
500
550
1000BASE-LX
SM
9
NA
5,000
1000BASE-SLX
SM
9
NA
10,000