AT-IFS802SP/POE(W)-80 User Manual
5.3  Login in the Console Interface 
When the connection between Switch and PC is ready, turn on the PC and run a terminal emulation 
program  or  Hyper Terminal  and  configure  its  communication  parameters  to  match  the  following
default characteristics of the console port:
Baud Rate: 9600 bps
Data Bits: 8
Parity: none
Stop Bit: 1
Flow control: None
Having finished the parameter settings, click ‘OK’. When the blank screen shows up, press Enter key
to  have  the  login  prompt  appears.  Key  in ‘manager’  (default  value)  for  Username  and “friend”  for
Password (use Enter key to switch), then press Enter and the Main Menu of console management 
appears. Please see below figure for login screen.
5.4  CLI Management
The system supports the console management—CLI command. After you log in on to the system, you 
will see a command prompt. To enter CLI management interface, type in “
enable” command.
The following table lists the CLI commands and description.
CLI command interface