Lightwave Communications 3200 Manuale Utente

Pagina di 88
 
36
  The primary IP information, including: IP address, subnet mask, and gateway 
  The secondary IP information, including: destination address, subnet mask, and 
gateway 
 
The terminal and device cards will return the following information: 
 
  The terminal or device port number 
  The port letter as indicated on card label 
  Equipment port type (DCE or DTE) 
 Baud 
rate 
  Parity; N=none, E=even, O=odd 
 Data 
bits 
 Stop 
bits 
  Flow control type 
  Status of RTS line; 0=off, 1=on 
  Status of DTR line; 0=off, 1=on 
 
The labels “RTS” and “DTR” do not change when the port type is changed from DCE to 
DTE.  When the port type is changed, the label “RTS” indicates the status of the CTS 
line, and “DTR” indicates the status of the DSR line. 
 
6.7.5 
POWERSTATUS
POWERSTATUS
POWERSTATUS
POWERSTATUS Command 
 
sys admin>>POWERSTATUS 
Power supply A is OK 
Power supply B is OK 
 
sys admin>> 
 
 
The POWERSTATUS command displays the status of the two redundant power supplies 
in the ConsoleServer 3200 chassis.  Power supplies will either be listed as OK or 
Failed
.  The ConsoleServer 3200 will continue to function with one failed power 
supply.  Contact Lightwave for information regarding replacement if a power supply 
fails. 
 
6.7.6 
LOG
LOG
LOG
LOG Command 
 
sys admin>>log /enable 
 
 
The ConsoleServer 3200 can report current system activity through control card port B.  
The report is enable using the command LOG /ENABLE, and disabled using the 
command LOG /DISABLE. 
 
The system will report user logins, logouts, device port selections, and entry/exit from 
direct mode.  Note that there is no system clock on the ConsoleServer 3200, so there is