Powering up the system and initial loading
NN43021-310
Standard 02.01
December 2007
Preparing to power up – DC
Procedure 53
Preparing to power up – DC
Preparing to power up – DC
1
Set the AC service panel circuit breakers to each rectifier OFF.
2
Remove the DC power distribution fuses or set the distribution circuit
breakers OFF.
breakers OFF.
3
Set all circuit breakers in the rear of each pedestal OFF.
4
Set the power supply switches in each module OFF.
5
Set the ringing generators in each IPE or PE module OFF.
6
Set the blower unit in each pedestal OFF.
7
Set all faceplate switches to ENB.
8
Proceed to “Turning DC power ON” on
End of Procedure
Turning DC power ON
Follow Procedure 54 to turn the DC power on.
CAUTION