 Performing acceptance tests
NN43021-310
Standard 02.01
December 2007
3
Use a screwdriver to loosen the retaining screws at the front of the blower 
unit (see Figure 117 on 
) and pull the unit out until it is 
disconnected from the pedestal.
Note: Do not pull the unit all the way out of the pedestal.
The column LED should light.
4
Reinstall the blower unit and tighten the retaining screws.
The column LED should go out.
The system terminal should display PWR0046.
5
Heat one of the two thermal sensors under the top cap of the column with 
a hand-held hair dryer or similar heat source.
The column LED should light.
Thirty seconds after the thermal sensor detects 70 degrees C 
(158 degrees F), the main circuit breaker, or the blower unit circuit 
breaker, at the rear of the pedestal should trip. The system terminal 
should display PWR0004, PWR0006, and PWR0007.
6
Allow the sensor to cool, then reset the circuit breaker in the pedestal. If 
a sysload occurs, allow it to complete.
The column LED should go out.
The system terminal should display PWR0044, PWR0046, and 
PWR0047.
7
Repeat step 5 and step 6 for the other thermal sensor.
End of Procedure