DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-77
Add IP Interface Assembly 
6
10. Click Start > Shut Down and select 
Restart the computer?
or on the TN802:
Press the recessed reset button on the faceplate (see 
) until 
the LCD shows a flashing MSHUT *. When the flashing stops and the 
asterisk disappears (about 2 min), reseat the circuit pack to restart the 
system.
or on the SAT:
a. Type busyout board 
UUCSS and press 
Enter
 .
b. Type reset board 
UUCSS and press 
Enter
c. Type release board 
UUCSS and press 
Enter
Once the system is completely initialized, the LCD reads MEDPRO *.
!
WARNING:
When connected remotely via pcANYWHERE, only use the 
pcANYWHERE Restart Host Computer button on the toolbar to 
restart Windows NT.
11. Affix the new TN802B label to the circuit pack.
12. Disconnect the monitor, keyboard, and mouse.