Adding or Removing Cabinet Hardware 
6-82
Add a Control Carrier (Add Duplication) 
6
3. Select 
Reset System from the Maintenance menu.
4. Select 
Shutdown from the Reset System menu.
5. Unseat the LAN Gateway assembly from its backplane connectors.
Shut Down DEFINITY AUDIX System
1. If a DEFINITY AUDIX resides in the PPN or an EPN (where PPN Port 
Carrier B will be relocated), shut down the AUDIX and allow the disk to 
completely spin down. Refer to 
!
WARNING:
Neglecting to shut down an AUDIX assembly before powering down 
the system cabinet where it resides can damage the AUDIX disk.
2. Unseat the AUDIX assembly from its backplane connectors.
Power Down Port Networks
1. At the PPN, set the main circuit breaker to OFF.
2. At an EPN (where PPN port carrier B will be relocated), set the main circuit 
breaker to OFF.
Remove Doors and Panels and Disconnect Cables
1. Remove the front door from the PPN cabinet.
2. With the cable retainer in front of you and the part number visible, locate 
the slot that is almost vertical. (This slot is adjacent to the part number.) 
Insert a flat blade screwdriver with a wide blade (1/4-inch recommended) 
into the slot, and twist. The retainer snap opens easily so that the cable 
can be removed.
3. At the cabinet, disconnect previously labeled cables associated with the 
carrier to be removed.
4. Remove the back doors from the cabinet.